DSpace Repository

Efficiency of Applying Inhibitor to Control Internal Corrosion in Gas Pipeline Systems

Show simple item record

dc.contributor.author Ali K. M. Al-Zenati
dc.contributor.author Amhamed A. Omar
dc.contributor.author Nagi A. Issa
dc.contributor.author Nasar A. Ali
dc.contributor.author Mansour M. Salih
dc.date.accessioned 2024-12-02T21:16:17Z
dc.date.available 2024-12-02T21:16:17Z
dc.date.issued 2022-01-01
dc.identifier.issn 2518-5454
dc.identifier.uri http://dspace-su.server.ly:8080/xmlui/handle/123456789/2257
dc.description.abstract Utilization of film-former corrosion inhibitors is one of the most reliable and economical ways of controlling internal corrosion of oil and gas pipeline systems. The current study sheds light on the feasibility range of the success of the application of corrosion inhibitor "amines base filming inhibitor" in the gas pipeline 34" BMK "Brega-Misurata-Khoms" by utilizing various ways such as monitoring techniques, test and analysis methods, injection rate of inhibitor and efficiency of corrosion inhabitation. Internal corrosion is monitored by different techniques such as electrical resistance (E/R) probe using cosasco corrocometer model CK-3, direct specimens of dry gas and intelligent pig surveys. The samples of the last two methods of monitoring are achieved by chemical analysis in laboratory of Sirte Oil Company. This chemical analysis is accomplished to determine the content of compounds in the gas, for instance iron/iron oxide, sulphur, carbon dioxide and hydrogen sulphide, etc. In reality, the internal corrosion rate of the inner surface of the pipeline system is negligible in comparison with standard criteria of corrosion. Furthermore, assessment of the film-forming corrosion inhibitor was found roughly sufficient to provide an excellent internal corrosion inhabitation because of the environmentally friendly properties of the gas, as a dry and sweet gas. en_US
dc.language.iso other en_US
dc.publisher جامعة سرت - Sirte University en_US
dc.relation.ispartofseries المجلد الثاني عشر- العدد الاول - يونيو 2022;
dc.relation.ispartofseries ;86-107
dc.subject Efficiency en_US
dc.subject Corrosion en_US
dc.subject Inhibitor en_US
dc.subject Film en_US
dc.subject Protection and Gas pipeline systems en_US
dc.title Efficiency of Applying Inhibitor to Control Internal Corrosion in Gas Pipeline Systems en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account