dc.contributor.author |
Essa Shawail |
|
dc.contributor.author |
Magdi Buaisha |
|
dc.date.accessioned |
2024-11-23T18:31:51Z |
|
dc.date.available |
2024-11-23T18:31:51Z |
|
dc.date.issued |
2024-10-01 |
|
dc.identifier.issn |
2958-6569 |
|
dc.identifier.uri |
http://dspace-su.server.ly:8080/xmlui/handle/123456789/738 |
|
dc.description.abstract |
In this paper, a field study is conducted on proving a positive displacement meter with bi-directional pipe provers to determine the repeatability of the meter's generated pulses and the deviation of the Meter Factor percentage during the Meter Proving process at Zueitina Oil Port in Libya. Equipment, procedures, requirements, national and international standards, and precautions that will ensure accurate metering of fluids were considered. |
en_US |
dc.language.iso |
other |
en_US |
dc.publisher |
The General Directorate of Inspection and Measurement -National Oil Corporation (NOC), Tripoli, Libya2Department of chemical engineering, university of Sirte, Libya |
en_US |
dc.relation.ispartofseries |
العدد 2;14-22 |
|
dc.subject |
Custody Transfer applications |
en_US |
dc.subject |
Bi-Directional Pipe Provers |
en_US |
dc.subject |
Meter-proving process |
en_US |
dc.title |
Field proving of a liquid displacement meter using Bi-directional Pipe Provers in Custody Transfer applications; case study of Libyan Zueitina Oil Port |
en_US |
dc.type |
Article |
en_US |